Search results for "beam [electron]"

showing 10 items of 433 documents

Direct Measurement of Focusing Fields in Active Plasma Lenses

2018

Physical review accelerators and beams 21(12), 122801 (2018). doi:10.1103/PhysRevAccelBeams.21.122801

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)Field (physics)FOS: Physical sciences01 natural sciences530law.inventionOpticslaw0103 physical sciencesddc:530Thermal emittancelcsh:Nuclear and particle physics. Atomic energy. Radioactivity010306 general physicsphysics.acc-phPhysics010308 nuclear & particles physicsbusiness.industrySurfaces and InterfacesPlasmaNuclear & Particles PhysicsLens (optics)Physics::Space PhysicsPhysical SciencesCathode raylcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsBeam emittancebusinessCharged particle beamBeam (structure)
researchProduct

Modeling of the Achilles Subtendons and Their Interactions in a Framework of the Absolute Nodal Coordinate Formulation

2022

Experimental results have revealed the sophisticated Achilles tendon (AT) structure, including its material properties and complex geometry. The latter incorporates a twisted design and composite construction consisting of three subtendons. Each of them has a nonstandard cross-section. All these factors make the AT deformation analysis computationally demanding. Generally, 3D finite solid elements are used to develop models for AT because they can discretize almost any shape, providing reliable results. However, they also require dense discretization in all three dimensions, leading to a high computational cost. One way to reduce degrees of freedom is the utilization of finite beam elements…

Achilles tendonbeam-to-beam contactarbitrary cross-sectionANCFelasticitykantajännebiomekaniikkamatemaattiset mallitbiomechanicskimmoisuus
researchProduct

Calculations of high-power production target and beamdump for the GSI future Super-FRS for a fast extraction scheme at the FAIR Facility

2005

A superconducting fragment separator (Super-FRS) is being designed for the production and separation of radioactive isotopes at the future FAIR (Facility for Antiprotons and Ion Research) facility at Darmstadt. This paper discusses various aspects and requirements for the high-power production target that will be used in the Super-FRS experiments. The production target must survive over an extended period of time as it will be used during the course of many experiments. The specific power deposited by the high intensity beam that will be generated at the future FAIR facility will be high enough to destroy the target in most of the cases as a result of a single shot from the new heavy ion sy…

Acoustics and UltrasonicsChemistryLiquid jetNuclear engineeringSeparator (oil production)Condensed Matter PhysicsThermal conductionSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIonNuclear physicsAntiprotonIrradiationBeam energyPower densityJournal of Physics D: Applied Physics
researchProduct

Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…

2015

Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…

AdultCalcium PhosphatesMaleCone beam computed tomographySinus Floor Augmentationmedicine.medical_specialtyMaterials scienceMaxillary sinusRadiographySinus Floor AugmentationSinus floor elevation03 medical and health sciencesImaging Three-Dimensional0302 clinical medicinemedicineHumansProspective Studies030212 general & internal medicineAgedβ tricalcium phosphatebusiness.industry3d image processingMembranes Artificial030206 dentistryCone-Beam Computed TomographyMiddle AgedSurgeryDurapatiteTreatment Outcomemedicine.anatomical_structureVolume (thermodynamics)Bone SubstitutesRadiographic Image Interpretation Computer-AssistedFemaleCollagenOral SurgerybusinessBiomedical engineeringClinical Oral Implants Research
researchProduct

A new 3D method for measuring cranio-facial relationships with cone beam computed tomography (CBCT)

2013

Objectives: CBCT systems, with their high precision 3D reconstructions, 1:1 images and accuracy in locating cephalometric landmarks, allows us to evaluate measurements from craniofacial structures, so enabling us to replace the anthropometric methods or bidimensional methods used until now. The aims are to analyse cranio-facial relationships in a sample of patients who had previously undergone a CBCT and create a new 3D cephalometric method for assessing and measuring patients. Study Design: 90 patients who had a CBCT (i-Cat®) as a diagnostic register were selected. 12 cephalometric landmarks on the three spatial planes (X,Y,Z) were defined and 21 linear measurements were established. Using…

AdultCone beam computed tomographyAdolescentCephalometryBase (geometry)DentistryFacial BonesYoung AdultImaging Three-DimensionalBiomaterials and Bioengineering in DentistrymedicineHumansCraniofacialChildGeneral DentistryOrthodonticsbusiness.industrySkullMandibleCraniometryCone-Beam Computed TomographyMiddle AgedSkullmedicine.anatomical_structureOtorhinolaryngologySurgeryResearch-ArticlebusinessMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

The assesment of relationship between the angulation of impacted mandibular third molar teeth and the thickness of lingual bone: A prospective clinic…

2018

Background Our purpose was to investigate the relationship between the angulation of mandibular third molars and the thickness of the lingual bone, which can affect the risk of lingual nerve damage during lower third molars surgical extraction. Material and Methods This study consisted of 104 patients (42 males and 62 females), aged between 18-42 years (24.67 ± 6.11 years). Cone Beam Computed Tomography (CBCT) images were taken for preoperative assessment. The teeth were divided into four groups according to their positions: mesioangular, distoangular, vertical and horizontal. Lingual bone thickness around impacted teeth were measured at three points: cementoenamel junction (CEJ) of the man…

AdultMale0301 basic medicineMolarCone beam computed tomographyAdolescentMandibleMandibular second molarMandibular third molarLingual Nerve InjuriesYoung Adult03 medical and health sciences0302 clinical medicinestomatognathic systemHumansMedicineProspective StudiesIntraoperative ComplicationsGeneral DentistryLingual nerveOrthodonticsbusiness.industryImpacted toothResearchHyoid BoneTooth ImpactedMandible030206 dentistry:CIENCIAS MÉDICAS [UNESCO]stomatognathic diseasesCementoenamel junctionOtorhinolaryngologyTooth ExtractionUNESCO::CIENCIAS MÉDICASFemaleMolar ThirdSurgery030101 anatomy & morphologyOral SurgerybusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Cephalometric measurements from 3D reconstructed images compared with conventional 2D images

2011

Abstract Objective: To assess whether the values of different measurements taken on three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) are comparable with those taken on two-dimensional (2D) images from conventional lateral cephalometric radiographs (LCRs) and to examine if there are differences between the different types of CBCT software when taking those measurements. Material and Methods: Eight patients were selected who had both an LRC and a CBCT. The 3D reconstructions of each patient in the CBCT were evaluated using two different software packages, NemoCeph 3D and InVivo5. An observer took 10 angular and 3 linear measurements on each of the three types o…

AdultMale2d imagesAdolescentCephalometryRadiographyDentistryOrthodonticsComputed tomographyImage processingMandibleYoung AdultImaging Three-DimensionalImage Processing Computer-AssistedMaxillamedicineHumansNasal BoneSella TurcicaChildMathematicsObserver VariationOrthodonticsmedicine.diagnostic_testPalatebusiness.industryIntraobserver reliabilityReproducibility of ResultsOriginal ArticlesCone-Beam Computed TomographyIncisorFaceMandibular planeFemalebusinessObserver variationSoftwareThe Angle Orthodontist
researchProduct

Use of autologous tooth-derived graft material in the post-extraction dental socket. Pilot study

2019

Background The objectives of the present pilot study are to compare via CBCT the alveolar contraction suffered both vertically and horizontally between the control group and the group using autologous dental material (ADM), as well as to study the densitometric differences between both post-extraction sockets. Material and Methods A split-mouth study was performed in n = 9 patients who required two extraction of single-rooted teeth deemed suitable for deferred rehabilitation with osseointegrated implants. Two groups were formed — a control group, in which the post-extraction socket was not filled, and an ADM group, in which the alveolar defect was filled with freshly processed autogenous de…

AdultMaleBone densityDentistryPilot Projects02 engineering and technologyOsseointegration03 medical and health sciences0302 clinical medicineHumansMedicineTooth SocketAutograftsGeneral DentistryDental alveolusSocket preservationbusiness.industryResearch030206 dentistryCone-Beam Computed TomographyMiddle Aged:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyOtorhinolaryngologyCoronal planeUNESCO::CIENCIAS MÉDICASDentinTooth ExtractionFemaleSurgeryOral Surgery0210 nano-technologybusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Accuracy between virtual surgical planning and actual outcomes in orthognathic surgery by iterative closest point algorithm and color maps: A retrosp…

2018

Background To evaluate the accuracy between actual outcomes and virtual surgical planning (VSP) in orthognathic surgery regarding the use of three-dimensional (3D) surface models for registration using iterative closest point (ICP) algorithm and generated color maps. Material and Methods Construction of planning and postoperative 3D models in STL files format (M0 and M1, respectively) from CBCT of 25 subjects who had been submitted to bimaxillary orthognathic surgery was performed. M0 and M1 were sent to Geomagic software in semi-automatic alignment surface mesh order of M0 and M1 for registration using ICP algorithm to calculate mean deviation (MD, MD+, MD-, SD) and root mean square (RMS –…

AdultMaleComputer sciencemedicine.medical_treatmentOrthognathic surgery3d modelMandibleNoseSurgical planningPatient Care PlanningRoot mean square03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineSoftwareMaxillamedicineHumansGeneral DentistryRetrospective StudiesReproducibilityOrthognathic Surgical Proceduresbusiness.industryResearchOrthognathic SurgeryReproducibility of ResultsIterative closest pointRetrospective cohort study030206 dentistryCone-Beam Computed Tomography:CIENCIAS MÉDICAS [UNESCO]Treatment OutcomeSurgery Computer-AssistedOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASComputer-Aided DesignFemaleSurgeryOral SurgerybusinessAlgorithmAlgorithmsMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Study between anb angle and Wits appraisal in cone beam computed tomography (CBCT)

2013

Objectives: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. Study Design: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson´s correlation coefficient has been performed to analyse the significance of each relationship. Results: When classifying t…

AdultMaleCone beam computed tomographyAdolescentCephalometryDentistryLinear measurementMandibleNormal valuesClass iiiYoung Adultsymbols.namesakeImaging Three-DimensionalBiomaterials and Bioengineering in DentistryMaxillaHumansMedicineChildGeneral DentistryOrthodonticsbusiness.industryCone-Beam Computed TomographyCraniometryPearson product-moment correlation coefficientOtorhinolaryngologyMaxillasymbolsResearch-ArticleFemaleSurgeryMandibular plane anglebusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct